@ -28,11 +28,14 @@ let
# temperatures are read from the file.
#
# For example:
# sensor /proc/acpi/ibm/thermal (0, 0, 10)
# tp_thermal /proc/acpi/ibm/thermal (0, 0, 10)
# will add a fixed value of 10 °C the 3rd value read from that file. Check out
# http://www.thinkwiki.org/wiki/Thermal_Sensors to find out how much you may
# want to add to certain temperatures.
${cfg.fan}
${cfg.sensors}
# Syntax:
# (LEVEL, LOW, HIGH)
# LEVEL is the fan level to use (0-7 with thinkpad_acpi)
@ -41,8 +44,6 @@ let
# All numbers are integers.
#
sensor ${cfg.sensor} (0, 10, 15, 2, 10, 5, 0, 3, 0, 3)
${cfg.levels}
'';
@ -53,20 +54,52 @@ in {
services.thinkfan = {
enable = mkOption {
type = types.bool;
default = false;
description = ''
Whether to enable thinkfan, fan controller for IBM/Lenovo ThinkPads.
'';
};
sensor = mkOption {
default = "/proc/acpi/ibm/thermal";
sensors = mkOption {
type = types.lines;
default = ''
tp_thermal /proc/acpi/ibm/thermal (0,0,10)
'';
description =''
Sensor used by thinkfan
thinkfan can read temperatures from three possible sources:
/proc/acpi/ibm/thermal
Which is provided by the thinkpad_acpi kernel
module (keyword tp_thermal)
/sys/class/hwmon/*/temp*_input
Which may be provided by any hwmon drivers (keyword
hwmon)
S.M.A.R.T. (since 0.9 and requires the USE_ATASMART compilation flag)
Which reads the temperature directly from the hard
disk using libatasmart (keyword atasmart)
Multiple sensors may be added, in which case they will be
numbered in their order of appearance.
'';
};
fan = mkOption {
type = types.str;
default = "tp_fan /proc/acpi/ibm/fan";
description =''
Specifies the fan we want to use.
On anything other than a Thinkpad you'll probably
use some PWM control file in /sys/class/hwmon.
A sysfs fan would be specified like this:
pwm_fan /sys/class/hwmon/hwmon2/device/pwm1
'';
};
levels = mkOption {
type = types.lines;
default = ''
(0, 0, 55)
(1, 48, 60)
@ -76,8 +109,12 @@ in {
(7, 60, 85)
(127, 80, 32767)
'';
description =''
Sensor used by thinkfan
description = ''
(LEVEL, LOW, HIGH)
LEVEL is the fan level to use (0-7 with thinkpad_acpi).
LOW is the temperature at which to step down to the previous level.
HIGH is the temperature at which to step up to the next level.
All numbers are integers.
'';
};